This water heater must be installed and serviced by a qualified person. Please leave this guide with the householder. Owner’s Guide and Installat
9 thermostat is fully automatic and the burner only operates when the water in the storage cylinder requires heating. There is no need to
10 The Aquamax warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in
11 was to become inoperable for any reason. We recommend you seek advice from your plumber or specifier about your needs and building bac
12 Major Five (5) Year Service It is recommended a major five (5) year service be conducted on the water heater. Servicing must be performed
13 Warning: Exercise care when operating easing lever as water discharged from the water heater may be of a very high temperature. War
14 The life of the storage cylinder may be extended by arranging a qualified person to periodically inspect the anode and replac
15 The Aquamax warranty will not cover resultant faults to the storage cylinder if this water heater is connected at anytime to a water
16 Water Chemistry Levels Affecting Warranty The Aquamax warranty of this water heater will not cover resultant faults on components including t
17 Troubleshooting Check the items below before making a service call. You will be charged for attending to any condition or fault that i
18 Pressure Temperature Relief Valve Running • Normal Operation It is normal and desirable for the PTR valve to allow a small quantity of water
1 Warning: Upon completion of the installation and commissioning of the water heater, leave this guide with the householder or responsible off
19 around the base of the water heater. This is quite normal, especially in winter months and the condensate will dry off as the water
20 INSTALLATION Installation Overview This water heater must be installed by a qualified person in accordance with the installation
21 It is a requirement of AS 5601 and AS/NZS 5601.1 that the water heater is secured to a wall. A wall bracket is supplied with the water heater f
22 Examples a, b & c from previous table Wall Bracket Installation It is a requirement of AS 5601 and AS/NZS 5601.1 that water h
23 Safe Tray Where damage to property can occur in the event of the water heater leaking, the water heater must be installed in
24 including the water heater. Care must be taken to avoid air locks. The cold water supply line to the water heater must be adequately sized a
25 Natural Gas Models: Remove yellow warning label from gas control after connecting gas supply line. Propane Gas Models: A gas regulator is
26 Expansion Control Valve In some areas, local regulations may make it mandatory to install an expansion control valve (ECV) in t
27 additional bends. Where the distance to the point of final discharge exceeds this length, the drain line can discharge into a tundish.
28 cylinder is damaged as a result of installing a Flashing Kit, any resultant faults will not be covered by the Aquamax warranty. Two T
2 CONTENTS Householder: Read the section ‘About Your Water Heater’ (pages 3 to 19). The ‘Installation’ section is intended for the
29 Two Temperature Zone Plumbing Diagram Circulated Hot Water Flow & Return Systems For circulated hot water flow and return systems,
30 Circulated Hot Water Flow & Return Plumbing Diagram
31 Commissioning To Fill, Turn ON and Commission the Water Heater Warning: The pilot or burner must not be lit until the water heater
32 Leave this guide with the householder or responsible officer upon completion of the installation and after commissioning. Warning: DO
33 1. Ensure all other gas appliances in the premises are operating (burners alight). 2. Ensure water heater is turned off and gas control
34 5. Take manometer reading with burner operating. If reading is 1.0 kPa for natural gas models or 2.7 kPa (±5% tolerance) for propane gas models
35 Draining the Water Heater Warning: Water discharged from the water heater during this procedure may be of a very high temperatu
36 Dimensions & Technical Data G270VE Model – Without Mixing Valve Storage capacity (L) 135 Connections Hot water delivery (L) 140 Cold water
37 This page is intentionally blank
38 This page is intentionally blank
3 ABOUT YOUR WATER HEATER Product Application This water heater is designed for use in a single family domestic dwelling for the purpose of
39 WARRANTY AQUAMAX GAS DOMESTIC MAINS PRESSURE WATER STORAGE HEATER WARRANTY – AUSTRALIA ONLY- 1. THE AQUAMAX WARRANTY - GENERAL 1.1 This w
40 2.4 Where the water heater is installed outside the boundaries of a metropolitan area as defined by Aquamax or further than 25
41 2.8 Subject to any statutory provisions to the contrary, this warranty excludes any and all claims for damage to furniture, c
42 4. ENTITLEMENT TO CLAIM UNDER THIS WARRANTY 4.1 To be entitled to make a claim under this warranty, you need to: a. Be the owner of the water
43 INSTALLER INFORMATION DEAR INSTALLER, Please provide the following information upon completion of the installation. This information should be
4 Mains Pressure Operation This water heater is designed to operate at mains pressure by connecting directly to the mains water supply. If the mai
5 To minimise scalding, especially for those people in high scald risk categories i.e. young children, people with potentially inc
6 Lighting Instructions 1. Stop. Read ‘Safety Warnings’ on page 5. 2. Remove single screw retaining access panel and lift out access
7 7. Hold gas knob in depressed position for a further twenty (20) seconds and then release. 8. Depress gas knob slightly and rotate anticl
8 Shut Down Procedure To view the gas control components described in this procedure refer to the ‘Lighting Instructions’ diagram on page 6. 1.
Commentaires sur ces manuels