This water heater must be installed and serviced by a qualified person.
Please leave this guide with the householder.
Owner’s Guide
and
Installation Instructions
Outdoor Domestic Mains Pressure
Gas Storage Water Heater
G270VE Series
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - Installation Instructions

This water heater must be installed and serviced by a qualified person. Please leave this guide with the householder. Owner’s Guide and Installat

Page 2

9 thermostat is fully automatic and the burner only operates when the water in the storage cylinder requires heating. There is no need to

Page 3 - CONTENTS

10 The Aquamax warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in

Page 4 - ABOUT YOUR WATER HEATER

11 was to become inoperable for any reason. We recommend you seek advice from your plumber or specifier about your needs and building bac

Page 5

12 Major Five (5) Year Service It is recommended a major five (5) year service be conducted on the water heater. Servicing must be performed

Page 6

13 Warning: Exercise care when operating easing lever as water discharged from the water heater may be of a very high temperature. War

Page 7

14 The life of the storage cylinder may be extended by arranging a qualified person to periodically inspect the anode and replac

Page 8

15 The Aquamax warranty will not cover resultant faults to the storage cylinder if this water heater is connected at anytime to a water

Page 9

16 Water Chemistry Levels Affecting Warranty The Aquamax warranty of this water heater will not cover resultant faults on components including t

Page 10 - 30°C 40°C 50°C 60°C 70°C

17 Troubleshooting Check the items below before making a service call. You will be charged for attending to any condition or fault that i

Page 11

18 Pressure Temperature Relief Valve Running • Normal Operation It is normal and desirable for the PTR valve to allow a small quantity of water

Page 12

1 Warning: Upon completion of the installation and commissioning of the water heater, leave this guide with the householder or responsible off

Page 13

19 around the base of the water heater. This is quite normal, especially in winter months and the condensate will dry off as the water

Page 14

20 INSTALLATION Installation Overview This water heater must be installed by a qualified person in accordance with the installation

Page 15

21 It is a requirement of AS 5601 and AS/NZS 5601.1 that the water heater is secured to a wall. A wall bracket is supplied with the water heater f

Page 16

22 Examples a, b & c from previous table Wall Bracket Installation It is a requirement of AS 5601 and AS/NZS 5601.1 that water h

Page 17

23 Safe Tray Where damage to property can occur in the event of the water heater leaking, the water heater must be installed in

Page 18

24 including the water heater. Care must be taken to avoid air locks. The cold water supply line to the water heater must be adequately sized a

Page 19 - • Continuous dribble

25 Natural Gas Models: Remove yellow warning label from gas control after connecting gas supply line. Propane Gas Models: A gas regulator is

Page 20

26 Expansion Control Valve In some areas, local regulations may make it mandatory to install an expansion control valve (ECV) in t

Page 21 - INSTALLATION

27 additional bends. Where the distance to the point of final discharge exceeds this length, the drain line can discharge into a tundish.

Page 22

28 cylinder is damaged as a result of installing a Flashing Kit, any resultant faults will not be covered by the Aquamax warranty. Two T

Page 23

2 CONTENTS Householder: Read the section ‘About Your Water Heater’ (pages 3 to 19). The ‘Installation’ section is intended for the

Page 24

29 Two Temperature Zone Plumbing Diagram Circulated Hot Water Flow & Return Systems For circulated hot water flow and return systems,

Page 25

30 Circulated Hot Water Flow & Return Plumbing Diagram

Page 26

31 Commissioning To Fill, Turn ON and Commission the Water Heater Warning: The pilot or burner must not be lit until the water heater

Page 27

32 Leave this guide with the householder or responsible officer upon completion of the installation and after commissioning. Warning: DO

Page 28

33 1. Ensure all other gas appliances in the premises are operating (burners alight). 2. Ensure water heater is turned off and gas control

Page 29

34 5. Take manometer reading with burner operating. If reading is 1.0 kPa for natural gas models or 2.7 kPa (±5% tolerance) for propane gas models

Page 30

35 Draining the Water Heater Warning: Water discharged from the water heater during this procedure may be of a very high temperatu

Page 31

36 Dimensions & Technical Data G270VE Model – Without Mixing Valve Storage capacity (L) 135 Connections Hot water delivery (L) 140 Cold water

Page 32

37 This page is intentionally blank

Page 33

38 This page is intentionally blank

Page 34

3 ABOUT YOUR WATER HEATER Product Application This water heater is designed for use in a single family domestic dwelling for the purpose of

Page 35

39 WARRANTY AQUAMAX GAS DOMESTIC MAINS PRESSURE WATER STORAGE HEATER WARRANTY – AUSTRALIA ONLY- 1. THE AQUAMAX WARRANTY - GENERAL 1.1 This w

Page 36

40 2.4 Where the water heater is installed outside the boundaries of a metropolitan area as defined by Aquamax or further than 25

Page 37 - (flared compression)

41 2.8 Subject to any statutory provisions to the contrary, this warranty excludes any and all claims for damage to furniture, c

Page 38

42 4. ENTITLEMENT TO CLAIM UNDER THIS WARRANTY 4.1 To be entitled to make a claim under this warranty, you need to: a. Be the owner of the water

Page 39

43 INSTALLER INFORMATION DEAR INSTALLER, Please provide the following information upon completion of the installation. This information should be

Page 40 - – AUSTRALIA ONLY

4 Mains Pressure Operation This water heater is designed to operate at mains pressure by connecting directly to the mains water supply. If the mai

Page 41

5 To minimise scalding, especially for those people in high scald risk categories i.e. young children, people with potentially inc

Page 42

6 Lighting Instructions 1. Stop. Read ‘Safety Warnings’ on page 5. 2. Remove single screw retaining access panel and lift out access

Page 43

7 7. Hold gas knob in depressed position for a further twenty (20) seconds and then release. 8. Depress gas knob slightly and rotate anticl

Page 44

8 Shut Down Procedure To view the gas control components described in this procedure refer to the ‘Lighting Instructions’ diagram on page 6. 1.